Categories

Two-Loop Analogue Addressable Fire Alarm System for LESKEN ENT. Depot & Office in Accra, Ghana

ANWETECH AT-F102 two-loop analogue addressable fire alarm system for LESKEN ENT. Depot & Office in Accra, Ghana, with addressable detection and alarm devices.
Sep 30th,2026 133 Views




Two-Loop Analogue Addressable Fire Alarm System for LESKEN ENT. Depot & Office in Accra, Ghana

ANWETECH supplied an AT-F102 two-loop analogue addressable fire alarm system for the LESKEN ENT. Depot & Office project located in Accra Spintex, Ghana.

The project combines an addressable fire alarm control panel with smoke detection, heat detection, manual alarm activation, audible and visual alarm notification, and addressable I/O modules to form an integrated fire detection and alarm solution for the depot and office premises.

Project Overview

Project: LESKEN ENT. Depot & Office
Location: Accra Spintex, Ghana
Application: Depot & Office
System Type: Analogue Addressable Fire Detection & Alarm System
Main Control Panel: AT-F102
Project Configuration: 2 Loops / 648 Addressable Points

The AT-F102 belongs to ANWETECH's analogue addressable fire alarm control panel range. According to the product manual, the AT-F102 supports up to four circuits, with each circuit supporting up to 324 addressable points.

For the LESKEN ENT. project, the system was specified as a two-loop configuration providing 648 addressable points, giving the project sufficient address capacity for the specified addressable field devices.

Fire Alarm System Configuration

The project configuration includes the following ANWETECH equipment:

Model Product
AT-F102 Analogue Addressable Fire Alarm Control Panel
AT-S101 Addressable Smoke Detector
AT-H101 Addressable Heat Detector
AT-SS102 Addressable Loop-Powered Sounder Strobe
AT-M101 Manual Call Point
AT-DM102 I/O Module

The combination of these devices provides the principal detection, manual alarm, alarm notification, and interface functions required for the project.

AT-F102 as the Central Fire Alarm Control Panel

At the center of the system is the ANWETECH AT-F102 analogue addressable fire alarm control panel.

The AT-F102 manual identifies the product as an analogue addressable fire alarm control panel and states that it is designed to meet the requirements of EN 54-2 and EN 54-4.

Each intelligent loop supports up to 324 addressable devices, with both Class A and Class B loop types listed in the technical specifications. ANWETECH_AT-F102_F103_User_Manu…

The two-loop configuration selected for this Ghana project therefore provides a total project capacity of 648 addressable points.

Addressable Fire Detection

The fire detection portion of the project includes both:

AT-S101 Addressable Smoke Detectors for smoke detection, and AT-H101 Addressable Heat Detectors for heat detection.

Using addressable detection devices allows individual field devices to operate as part of the addressable loop system connected to the AT-F102 control panel.

This configuration provides a structured fire detection solution for the different areas within the LESKEN ENT. depot and office premises.

Manual Fire Alarm Activation

AT-M101 Manual Call Points are included in the system configuration to provide manual fire alarm activation.

Together with the automatic smoke and heat detection devices, the manual call points form part of the project's addressable fire alarm infrastructure.

Audible and Visual Alarm Notification

For fire alarm notification, the project uses AT-SS102 Addressable Loop-Powered Sounder Strobes.

These devices combine audible and visual alarm notification within the addressable system and are included as part of the project's alarm warning equipment.

The AT-F102 manual also shows that a typical addressable loop architecture can incorporate detectors, sound and light devices, and input/output modules within the loop system.

I/O Interface

The system also incorporates the AT-DM102 I/O Module.

The I/O modules form part of the specified project configuration and provide the interface component required within the fire alarm system. No additional external equipment or control logic has been stated for this project, so no unconfirmed linkage functions are included in this project case.

Two-Loop Configuration for the LESKEN ENT. Project

A key feature of this installation is its two-loop addressable configuration.

Rather than describing the project simply as a general addressable fire alarm installation, the system is specifically configured around:

AT-F102 Control Panel → 2 Addressable Loops → 648 Addressable Points

with AT-S101 smoke detectors, AT-H101 heat detectors, AT-M101 manual call points, AT-SS102 sounder strobes, and AT-DM102 I/O modules forming the field-device configuration.

This provides a centralized addressable fire detection and alarm platform for the LESKEN ENT. Depot & Office project in Accra.