No.QRR3.0G/S-XR
Anwetech QRR3.0G/S-XR is a 3 kg hot aerosol fire extinguishing device designed for enclosed and semi-enclosed fire-risk areas up to 30 m³. It supports electrical and thermal activation and is suitable for electrical cabinets, energy storage systems, telecom equipment, cable areas, machinery and vehicle compartments.
  • QRR3.0G/S-XR 3KG Hot Aerosol Fire Extinguishing Device for 30m³

Description

 Product Overview

QRR3.0G/S-XR Hot Aerosol Fire Extinguishing Device

The ANWETECH QRR3.0G/S-XR Hot Aerosol Fire Extinguishing Device is a compact, non-pressurized fixed fire suppression unit designed for rapid fire control in relatively enclosed protected spaces.

The device contains an aerosol-forming compound, cooling material, thermal activation component, electrical starter, internal cylinder and external housing. When activated, the extinguishing agent is rapidly generated and discharged into the protected area to suppress the fire.

The system is particularly suitable for locations where conventional water-based fire suppression may not be practical, including electrical cabinets, energy storage equipment, telecommunications systems, cable areas, machinery and vehicle compartments.

According to the source manual, the device is designed for fires involving Class A surface materials, Class B flammable liquids or meltable solids, Class C gases and energized electrical equipment.


 Key Features

3 KG Aerosol Extinguishing Agent

The QRR3.0G/S-XR contains approximately 3 kg of aerosol fire-extinguishing agent.

Up to 30 m³ Protection Volume

With a specified extinguishing density of 100 g/m³, one unit has a nominal protected volume of 30 m³.

Non-Pressurized Design

Unlike conventional cylinder-based gaseous suppression systems, the aerosol extinguishing device is stored without high-pressure gas.

Fast Fire Suppression

The specified aerosol discharge time is ≤15 seconds, allowing rapid distribution of the extinguishing medium inside the protected enclosure.

Electrical Activation

Optional electrical activation allows integration with a compatible fire alarm or fire suppression control panel.

Thermal Activation

A thermal activation element can provide an additional method of initiating the extinguishing device.

Activation Feedback

The device can provide a switching feedback signal to the fire alarm / suppression control system after activation.

Wide Operating Temperature

Suitable for demanding environments with an operating temperature range of:

-50°C to +95°C

Long Service Life

Specified service life:

≥10 years

Compact Fixed Installation

Suitable for mounting inside or near electrical cabinets, machinery compartments, energy storage cabinets and other enclosed equipment areas.


 Technical Specifications

Parameter Specification
Product Name Hot Aerosol Fire Extinguishing Device
Model QRR3.0G/S-XR
Agent Mass 3 kg ±5 g
Device Net Weight 6.5 kg ±10%
Extinguishing Density 100 g/m³
Nominal Protection Volume 30 m³
Overall Dimensions H188 × Ø238 ±2 mm
Thermal Detection Line Length 25 cm ±15 mm
Thermal Activation Temperature 170°C ±10°C
Drive Voltage* DC 24 V
Minimum Activation Voltage* 1.5 V
Drive Current* >700 mA DC
Rated Activation Current* 2 A
Activation Time at Rated Current* 5 ms
Safe Test Current* ≤150 mA DC for 600 s
Discharge Time ≤15 s
Operating Temperature -50°C to +95°C
Storage Temperature -40°C to +54°C
Storage Humidity Up to 95% RH
Service Life ≥10 years
Feedback Contact Switching signal
Maximum Feedback Current* ≤0.5 A at 24 VDC
Installation Type Fixed installation
Fire Suppression Type Hot aerosol

These values are taken from the product technical parameter table.

* Optional / configuration-dependent items. Final configuration should be confirmed according to the supplied product.


 Aerosol Discharge Temperature

Distance from Discharge Outlet Aerosol Temperature
0.25 m ≤400°C
0.5 m ≤200°C
1.0 m ≤75°C

The manual provides these separation-temperature values for installation design.


Fire Alarm Control Panel Connection

The aerosol extinguishing unit can be connected to a compatible fire suppression control panel for automatic electrical activation and discharge feedback.

For the ANWETECH panel connection shown in the project wiring diagram:

ELECTRO VALVE + → START +
ELECTRO VALVE GND → START -
REL SWITCH GND → FEEDBACK 1
REL SWITCH + → FEEDBACK 2

Multiple aerosol extinguishing units can be connected according to the approved system design and control-panel output capacity.

The source manual states that the electrical starting terminals do not require polarity distinction, and that the feedback circuit is normally used only as a switching signal rather than for directly controlling high-power loads.


 How It Works

When the aerosol unit is integrated with a fire alarm / suppression system, the typical operating sequence is:

Fire Detection → Fire Alarm → Pre-discharge Delay → Equipment / Ventilation Shutdown → Aerosol Activation → Fire Suppression → Activation Feedback

After confirmed fire detection, the suppression controller sends an electrical activation signal to the aerosol unit.

The aerosol-forming compound is activated and rapidly generates the extinguishing aerosol.

The aerosol spreads throughout the protected enclosure and suppresses the fire.

The feedback contact changes state to indicate that the extinguishing device has operated.


 Recommended Applications

Electrical Cabinets

Suitable for:

  • LV electrical cabinets
  • HV electrical cabinets
  • Distribution cabinets
  • Control cabinets
  • Switchgear
  • Electrical enclosures

Battery Energy Storage Systems

Suitable for:

  • BESS cabinets
  • Energy storage containers
  • Energy storage prefabricated cabins
  • Outdoor ESS cabinets
  • Battery PACK enclosures

Telecommunications

Suitable for:

  • Telecom cabinets
  • Communication cabinets
  • Telecom base stations
  • Communication rooms
  • Network equipment enclosures

Cable Protection

Suitable for:

  • Cable trenches
  • Cable shafts
  • Cable compartments
  • Electrical cable areas

Wind Power

Suitable for:

  • Wind turbine nacelles
  • Electrical compartments
  • Control cabinets

Industrial Equipment

Suitable for:

  • Machinery
  • Hydraulic equipment
  • CNC / turning equipment
  • Industrial electrical equipment

Vehicle Applications

Suitable for relatively enclosed:

  • Engine compartments
  • Logistics vehicle compartments
  • Cold-chain vehicles
  • Equipment compartments

These application types are specifically identified in the source manual.


 Installation Notes

For effective aerosol distribution:

  • Install the device securely on an appropriate structural surface.
  • Maintain an unobstructed aerosol discharge path.
  • Keep large continuous obstacles at least 50 cm away from the discharge outlet.
  • Do not install multiple aerosol outlets directly facing each other.
  • Avoid directing the aerosol discharge directly against nearby equipment or obstructions.
  • Disconnect all control-panel and backup power before wiring or maintenance.
  • Do not drill, dismantle or modify the aerosol device.
  • Verify compatibility when connecting the device to third-party fire alarm or suppression controllers.

The manual specifically requires a clear discharge path and a minimum 50 cm unobstructed area in front of the outlet.


 Maintenance

Recommended inspection includes:

  • Check electrical connections periodically.
  • Inspect the enclosure for cracks, dents, deformation or corrosion.
  • Check the thermal activation component.
  • Keep the aerosol outlet unobstructed.
  • Inspect mounting brackets and fasteners.
  • Verify the external isolation switch.
  • Replace any damaged device.
  • Replace the device when its specified service life expires.

The source manual specifies monthly electrical and visual inspections and a service life of approximately 10 years when correctly installed and maintained.


Important Safety Information

The device should be applied only in accordance with a qualified fire suppression system design.

It is not intended for normally occupied spaces under the source manual's application limitations. The manual also excludes certain reactive materials, active metals, self-decomposing chemicals, strong oxidizers and deep-seated Class A fires.

Personnel should not stand directly in front of the aerosol discharge outlet.

After activation, the protected area should be treated as a fire and suppression hazard area until appropriate ventilation and safety procedures have been completed.

Download