AS01 Aspirating Smoke Detector | Laser Early Warning Fire Detection

No.AT-AS01
The AS01 Stand-alone Laser Cavity Aspirating Smoke Detector is an active air sampling smoke detection system designed for very early fire warning. It draws air samples through a sampling pipe network and analyzes smoke particle concentration inside a laser chamber. With high sensitivity, five alarm levels, RS485 communication and multiple relay outputs, it is suitable for data centers, electrical rooms, warehouses, cable tunnels, battery rooms, laboratories, museums and other critical facilities.AS01 Aspirating Smoke Detector | Laser Early Warning Fire Detection
  • AS01 Aspirating Smoke Detector | Laser Early Warning Fire Detection
  • AS01 Aspirating Smoke Detector | Laser Early Warning Fire Detection

Description

Product Overview

The AS01 is a stand-alone laser cavity aspirating smoke detector designed for early smoke detection in protected spaces and equipment areas. Unlike traditional point smoke detectors, AS01 actively draws air through a sampling pipe network and continuously analyzes smoke concentration inside the detector.

The detector uses laser scattering technology to identify minute smoke particles during the earliest combustion stage. When the smoke concentration exceeds preset alarm thresholds, the system can trigger different alarm levels and output signals through relay contacts or RS485 communication.

This product is suitable for applications where early warning is important, especially in areas where smoke may not quickly reach a conventional detector, or where fire risk must be identified before visible flame or heavy smoke develops.


Key Features

Very Early Smoke Detection
Detects minute smoke particles at the early combustion stage, helping users identify fire risks before serious smoke spread.

Laser-Based Detection Chamber
Uses laser scattering technology to measure smoke concentration with high sensitivity and stable detection performance.

Active Air Sampling Design
Continuously draws air samples from the protected area through a pipe network for centralized smoke analysis.

Five Alarm Levels
Supports Warning, Pre-alarm, Patrol, Fire Alarm 1 and Fire Alarm 2 levels for flexible fire warning and response.

Touchscreen Real-Time Display
Provides visual smoke concentration display and easier local operation through the touchscreen interface.

Adjustable Sensitivity and Thresholds
Sensitivity and alarm thresholds can be configured according to the site environment and application requirements.

Self-Learning Function
Supports automatic environmental adaptation to help reduce unwanted alarms caused by normal environmental changes.

RS485 Communication
Built-in RS485 interface allows connection with monitoring systems for centralized management and visualization.

Multiple Relay Outputs
Provides alarm relay outputs and fault signal output for connection with fire alarm panels, extinguishing control panels, BMS or other monitoring systems.

Event Record Storage
Stores alarm and event records for operation review and maintenance analysis.

Low Maintenance Design
Includes self-cleaning function and filter maintenance guidance to support long-term system operation.


Technical Specifications

Item Specification
Product Type Stand-alone Laser Cavity Aspirating Smoke Detector
Detection Principle Laser scattering / light obscuration smoke detection
Power Supply 24V DC
Power Supply Range 14–30V DC
Power Consumption <30W
Detection Area Up to 1,000 m² per detector
Sensitivity Range 0.001–28% obs/m
Pipe Length 2 × 100 m maximum
Sampling Holes 26 holes per pipe, 52 holes total
Alarm Levels Warning, Pre-alarm, Patrol, Fire Alarm 1, Fire Alarm 2
Alarm Records 32,000 events
Communication RS485 interface
Operating Temperature -40°C to +65°C
Storage Temperature -40°C to +70°C
Humidity Range 0–100% RH, non-condensing
Dimensions 300 × 230 × 98 mm
Weight <3 kg

Note: Final pipe layout, sampling hole quantity and actual protection area should be designed according to project drawings, site airflow conditions and local fire safety codes.


Wiring / Output / Relay

Terminal Function Description
POWER ± Power Input DC 24V power supply input
RS485-1 A/B Communication Main RS485 communication interface
RS485-2 A/B Communication Reserved RS485 communication interface
ALM1–ALM4 Alarm Outputs Relay outputs for different alarm levels
FAULT Fault Signal System fault indication output
RESET ± Reset Input External reset control input

The AS01 can be integrated with a fire alarm control panel, extinguishing control panel, BMS, remote monitoring system or centralized management software through relay outputs and RS485 communication.

For extinguishing system applications, the detector should normally provide alarm signals to a releasing control panel or fire alarm control panel. The control panel should handle delay, sounder beacon activation, manual/automatic mode, emergency stop, release confirmation and other safety logic.


Application Scenarios

Data Centers and Server Rooms
Provides early warning smoke detection for server cabinets, underfloor spaces and critical IT equipment areas.

Power Distribution Rooms
Suitable for electrical rooms, switchgear rooms, transformer rooms and UPS areas where cable overheating or electrical faults may generate early smoke particles.

Battery Rooms and Energy Storage Cabinets
Applicable to battery rooms and energy storage cabinet areas where early abnormal smoke detection is important for fire risk control.

Cable Tunnels and Communication Cabinets
Can sample air from confined or hidden spaces where traditional point detectors may be difficult to install or maintain.

Warehouses and Logistics Centers
Suitable for large storage areas where active sampling can help improve early smoke detection coverage.

Museums, Archives and Libraries
Helps protect valuable assets by detecting smoke at an early stage before fire development causes severe damage.

Laboratories and Clean Environments
Applicable to laboratories, pharmaceutical facilities, hospitals and electronics manufacturing areas that require sensitive smoke monitoring.

Industrial Facilities
Suitable for power plants, mines, paper mills, transportation tunnels and other industrial fire risk areas.

Download