• AT-B01 Reflective Linear Beam Smoke Detector| 5–100m Beam Smoke Detection
  • AT-B01 Reflective Linear Beam Smoke Detector| 5–100m Beam Smoke Detection

AT-B01 Reflective Linear Beam Smoke Detector| 5–100m Beam Smoke Detection

No.AT-B01
AT-B01 is a reflective linear beam smoke detector designed for large open spaces. It supports 5–100m detection distance, built-in laser alignment, 8 sensitivity levels, fire/fault relay outputs, RS485 communication, and automatic light compensation.
  • AT-B01 Reflective Linear Beam Smoke Detector| 5–100m Beam Smoke Detection

Description

Product Overview

The ANWETECH AT-B01 Linear Beam Smoke Detector is a reflective beam-type smoke detector designed for large open spaces where point smoke detectors may be difficult to install or maintain.

The detector transmits an infrared beam to the reflector and monitors the reflected signal. When smoke enters the beam path, the light intensity is reduced. The detector analyzes the attenuation and provides fire alarm or fault signals through LED indication, buzzer, relay outputs and RS485 communication.

AT-B01 is suitable for warehouses, shopping malls, museums, archives, large workshops, aircraft hangars, power plants, halls, historical buildings and other high-ceiling or wide-area applications.

 Key Features

Built-in laser module for fast aiming and commissioning.

5m to 100m detection distance for large open spaces.

Reflective beam design with detector and reflector.

8 built-in sensitivity levels for different site environments.

Automatic light compensation for environmental changes.

Fire alarm relay output and fault relay output.

RS485 communication interface.

Red, yellow and green LED status indication.

Buzzer indication for commissioning and alarm status.

Suitable for warehouses, halls, malls, hangars and large buildings.

Technical Specifications

Item Specification
Model AT-B01
Product Type Linear Beam Smoke Detector
Detection Type Reflective beam smoke detection
Monitoring Distance 5m–100m
Working Voltage DC24V
Voltage Range DC18–30V
Working Current Monitoring: 35±5mA / Alarm: 60±5mA
Sensitivity 8 levels
Status Indicator Red: fire alarm / patrol status; Yellow: fault; Green: normal
Output Fire alarm relay, fault relay
Communication RS485
Operating Temperature -10°C to +55°C
Humidity RH 0%–95%
Protection Grade IP53
Weight 0.5kg without reflector
Optical Path Deviation 0.5°

 Wiring / Output / Relay

AT-B01 provides conventional fire alarm system connection terminals.

Terminal Description
DC24V Non-polarized DC18–30V power input
Fire Alarm Output Relay output, NO/NC selectable
Fault Output Relay output, NO/NC selectable
RS485 A/B RS485 communication interface

The detector can be connected to a fire alarm control panel through an input module. The terminal resistor value should follow the fire alarm system manufacturer’s requirement.

 Application Scenarios

Warehouses and logistics centers

Shopping malls and commercial buildings

Museums and archives

Large workshops and factories

Aircraft hangars

Power plants and power stations

High-ceiling halls

Historic buildings and heritage conservation buildings

Large open indoor spaces where point detectors are difficult to install

Download