• AT-WET 12L 15L Water-Based Electric Automatic Vehicle Fire Suppression System with Linear Heat Detection
  • AT-WET 12L 15L Water-Based Electric Automatic Vehicle Fire Suppression System with Linear Heat Detection

AT-WET 12L 15L Water-Based Electric Automatic Vehicle Fire Suppression System with Linear Heat Detection

No.AT-WET

The ANWETECH AT-WET Vehicle Fire Suppression System is a water-based fire protection system designed for vehicle engine compartments and confined spaces.

The system integrates a water-based extinguishing agent cylinder, linear heat detection cable, control main unit, manual activation device, sound and light alarm, discharge piping and stainless steel nozzles.

Two cylinder capacities are available:

12 L Cylinder – 9.3 L Extinguishing Agent
15 L Cylinder – 11.5 L Extinguishing Agent

The system supports automatic fire detection and activation as well as manual emergency activation.

  • AT-WET 12L 15L Water-Based Electric Automatic Vehicle Fire Suppression System with Linear Heat Detection

Description

Product Overview

The AT-WET Water-Based Vehicle Fire Suppression System is designed to provide early fire detection and extinguishing protection for vehicle engine compartments and other compact equipment spaces.

The system uses a linear heat detection cable installed inside the protected engine compartment to detect abnormal fire conditions.

When the system receives a fire alarm signal, the control unit activates the extinguishing system. A manual activation device is also installed near the driver's cab to allow personnel to manually initiate the system when required.

The extinguishing agent is discharged through fixed piping and multiple nozzles positioned toward the protected and higher-risk areas.


 Key Features

  • 12 L and 15 L cylinder options
  • Water-based extinguishing agent
  • Automatic fire detection and activation
  • Manual emergency activation
  • Linear heat detection cable
  • DC 24 V control main unit
  • Sound and light alarm indication
  • Backup power supply
  • Multiple discharge nozzles
  • G1/2 nozzle connection
  • 304 stainless steel discharge pipeline
  • 304 stainless steel pipe clamps
  • 304 stainless steel discharge nozzles
  • Designed for installation in vehicle engine compartments
  • Extinguishing agent temperature resistance from -35°C to +50°C

 Available Configurations

Parameter AT-WET 12L AT-WET 15L
Model AT-WET AT-WET
Cylinder Capacity 12 L 15 L
Extinguishing Agent Water-based Water-based
Agent Filling Quantity 9.3 L 11.5 L
Nozzle Quantity 8–10 pcs 10–15 pcs
Nozzle Connection G1/2 G1/2

Technical Specifications

Parameter Specification
Product Model AT-WET
System Type Water-Based Vehicle Fire Suppression System
Cylinder Capacity 12 L / 15 L
Extinguishing Agent Type Water-based
Agent Filling Quantity – 12 L Version 9.3 L
Agent Filling Quantity – 15 L Version 11.5 L
Agent Temperature Resistance -35°C to +50°C
Cylinder Quantity 1
Manual Activation Device AT-SF
Control Main Unit AT-GB-03
Control Unit Power Supply DC 24 V
Maximum Output Current 2 A
Sound and Light Alarm SA100
Backup Power Supply XP06P120UPS24V
Linear Heat Detection Cable JTW-LD-PTA200/180
Heat Detection Cable Length 10 m
Agent Discharge Pipeline AT-MF
Agent Discharge Pipeline Quantity 4 pcs
Pipeline Material 304 Stainless Steel
Pipe Fixing Base 6 pcs
Pipe Fixing Clamp Φ20, 6 pcs
Pipe Clamp Material 304 Stainless Steel
Pipe Fittings Three-way, Straight Connector, Elbow
Nozzle Connection G1/2
Nozzle Quantity – 12 L 8–10 pcs
Nozzle Quantity – 15 L 10–15 pcs
Nozzle Material 304 Stainless Steel
Nozzle Protective Cover Included
Discharge Time ≥35 s
Driving Nitrogen Pressure 2.5 MPa
Activation Medium Nitrogen
Fire Detector Temperature 182°C


Working Principle

The AT-WET system combines fire detection, alarm, control and extinguishing functions.

During normal operation, the linear heat detection element is installed in the protected engine compartment and monitors the protected area.

When a fire condition is detected, an alarm signal is transmitted to the control main unit. The controller then activates the extinguishing system, allowing the water-based extinguishing agent to discharge through the fixed piping network and nozzles toward the protected equipment.

The system also provides a manual activation device installed near the driver's cab for emergency operation by personnel.


 Installation

The extinguishing cylinder should be securely installed at a suitable position on the vehicle.

The linear heat detection cable is installed in the engine compartment.

Discharge nozzles should be installed along the discharge piping and directed toward the protected equipment, especially areas with higher fire risk.

The control main unit and manual activation device should be installed near the driver's cab in a position that is convenient for operation while avoiding interference with normal vehicle operation and maintenance. 

The installation package includes pipe supports, high-temperature straps, high-temperature cable, fireproof sleeve, liquid-tight tape, R clamps and saddle clamps according to the confirmed configuration.


 Typical Applications

The AT-WET system is intended for fire protection in:

  • Vehicle engine compartments
  • Enclosed or confined vehicle equipment spaces
  • Vehicle areas where fixed fire detection and suppression are required

The source manual specifically identifies vehicle engine compartments and confined spaces as the intended application areas. 


 System Components / Package Configuration

Component Model / Specification Quantity
Cylinder Valve Assembly AT-12L / AT-15L 1 Set
Water-Based Extinguishing Agent 9.3 L / 11.5 L 1 Fill
Manual Activation Device AT-SF 1 pc
Control Main Unit AT-GB-03 1 Set
Sound and Light Alarm System SA100 1 Set
Backup Power Supply XP06P120UPS24V 1 Set
Linear Heat Detection Cable JTW-LD-PTA200/180 10 m
Pipe Fixing Base — 6 pcs
Pipe Fixing Clamp Φ20 6 pcs
Agent Discharge Pipeline AT-MF 4 pcs
Pipe Fittings Three-way, Straight Connector, Elbow Several
Installation Accessories Pipe support, high-temperature strap, high-temperature cable, fireproof sleeve Several
Nozzle with Protective Cover – 12 L G1/2 8–10 sets
Nozzle with Protective Cover – 15 L G1/2 10–15 sets

Inspection and Maintenance

The system pressure should be checked monthly. According to the original manual, if the indicated pressure is below 1.6 MPa at 20°C, the system should be inspected for possible leakage.

Cylinder valves, manual activation devices, fire detection components, connecting pipes and control equipment should also be inspected regularly.

The manual specifies:

  • Monthly system inspection
  • Comprehensive annual inspection
  • System service life: 10 years
  • Extinguishing agent cylinder inspection: every 3 years

Download