The ANWETECH AT-WET Vehicle Fire Suppression System is a water-based fire protection system designed for vehicle engine compartments and confined spaces.
The system integrates a water-based extinguishing agent cylinder, linear heat detection cable, control main unit, manual activation device, sound and light alarm, discharge piping and stainless steel nozzles.
Two cylinder capacities are available:
12 L Cylinder – 9.3 L Extinguishing Agent
15 L Cylinder – 11.5 L Extinguishing Agent
The system supports automatic fire detection and activation as well as manual emergency activation.
The AT-WET Water-Based Vehicle Fire Suppression System is designed to provide early fire detection and extinguishing protection for vehicle engine compartments and other compact equipment spaces.
The system uses a linear heat detection cable installed inside the protected engine compartment to detect abnormal fire conditions.
When the system receives a fire alarm signal, the control unit activates the extinguishing system. A manual activation device is also installed near the driver's cab to allow personnel to manually initiate the system when required.
The extinguishing agent is discharged through fixed piping and multiple nozzles positioned toward the protected and higher-risk areas.
| Parameter | AT-WET 12L | AT-WET 15L |
|---|---|---|
| Model | AT-WET | AT-WET |
| Cylinder Capacity | 12 L | 15 L |
| Extinguishing Agent | Water-based | Water-based |
| Agent Filling Quantity | 9.3 L | 11.5 L |
| Nozzle Quantity | 8–10 pcs | 10–15 pcs |
| Nozzle Connection | G1/2 | G1/2 |
| Parameter | Specification |
|---|---|
| Product Model | AT-WET |
| System Type | Water-Based Vehicle Fire Suppression System |
| Cylinder Capacity | 12 L / 15 L |
| Extinguishing Agent Type | Water-based |
| Agent Filling Quantity – 12 L Version | 9.3 L |
| Agent Filling Quantity – 15 L Version | 11.5 L |
| Agent Temperature Resistance | -35°C to +50°C |
| Cylinder Quantity | 1 |
| Manual Activation Device | AT-SF |
| Control Main Unit | AT-GB-03 |
| Control Unit Power Supply | DC 24 V |
| Maximum Output Current | 2 A |
| Sound and Light Alarm | SA100 |
| Backup Power Supply | XP06P120UPS24V |
| Linear Heat Detection Cable | JTW-LD-PTA200/180 |
| Heat Detection Cable Length | 10 m |
| Agent Discharge Pipeline | AT-MF |
| Agent Discharge Pipeline Quantity | 4 pcs |
| Pipeline Material | 304 Stainless Steel |
| Pipe Fixing Base | 6 pcs |
| Pipe Fixing Clamp | Φ20, 6 pcs |
| Pipe Clamp Material | 304 Stainless Steel |
| Pipe Fittings | Three-way, Straight Connector, Elbow |
| Nozzle Connection | G1/2 |
| Nozzle Quantity – 12 L | 8–10 pcs |
| Nozzle Quantity – 15 L | 10–15 pcs |
| Nozzle Material | 304 Stainless Steel |
| Nozzle Protective Cover | Included |
| Discharge Time | ≥35 s |
| Driving Nitrogen Pressure | 2.5 MPa |
| Activation Medium | Nitrogen |
| Fire Detector Temperature | 182°C |
The AT-WET system combines fire detection, alarm, control and extinguishing functions.
During normal operation, the linear heat detection element is installed in the protected engine compartment and monitors the protected area.
When a fire condition is detected, an alarm signal is transmitted to the control main unit. The controller then activates the extinguishing system, allowing the water-based extinguishing agent to discharge through the fixed piping network and nozzles toward the protected equipment.
The system also provides a manual activation device installed near the driver's cab for emergency operation by personnel.
The extinguishing cylinder should be securely installed at a suitable position on the vehicle.
The linear heat detection cable is installed in the engine compartment.
Discharge nozzles should be installed along the discharge piping and directed toward the protected equipment, especially areas with higher fire risk.
The control main unit and manual activation device should be installed near the driver's cab in a position that is convenient for operation while avoiding interference with normal vehicle operation and maintenance.
The installation package includes pipe supports, high-temperature straps, high-temperature cable, fireproof sleeve, liquid-tight tape, R clamps and saddle clamps according to the confirmed configuration.
The AT-WET system is intended for fire protection in:
The source manual specifically identifies vehicle engine compartments and confined spaces as the intended application areas.
| Component | Model / Specification | Quantity |
|---|---|---|
| Cylinder Valve Assembly | AT-12L / AT-15L | 1 Set |
| Water-Based Extinguishing Agent | 9.3 L / 11.5 L | 1 Fill |
| Manual Activation Device | AT-SF | 1 pc |
| Control Main Unit | AT-GB-03 | 1 Set |
| Sound and Light Alarm System | SA100 | 1 Set |
| Backup Power Supply | XP06P120UPS24V | 1 Set |
| Linear Heat Detection Cable | JTW-LD-PTA200/180 | 10 m |
| Pipe Fixing Base | — | 6 pcs |
| Pipe Fixing Clamp | Φ20 | 6 pcs |
| Agent Discharge Pipeline | AT-MF | 4 pcs |
| Pipe Fittings | Three-way, Straight Connector, Elbow | Several |
| Installation Accessories | Pipe support, high-temperature strap, high-temperature cable, fireproof sleeve | Several |
| Nozzle with Protective Cover – 12 L | G1/2 | 8–10 sets |
| Nozzle with Protective Cover – 15 L | G1/2 | 10–15 sets |
The system pressure should be checked monthly. According to the original manual, if the indicated pressure is below 1.6 MPa at 20°C, the system should be inspected for possible leakage.
Cylinder valves, manual activation devices, fire detection components, connecting pipes and control equipment should also be inspected regularly.
The manual specifies: