APPLICATION

Aspirating Smoke Detection for Underfloor Voids and Concealed Cable Spaces | ANWETECH AS01
2026-07-18 17:14:06
ANWETECH AS01 provides aspirating smoke detection for underfloor voids, raised floors, concealed cable spaces, electrical rooms, UPS rooms, server rooms, battery rooms, and other critical facilities requiring very early fire warning.
How to Test UV/IR Flame Detectors Without an Open Flame
2026-07-16 18:08:00
Learn how to test UV/IR flame detectors without an open flame using the AT-FD-T01 explosion-proof flame simulator, with up to 8 m operating distance and portable battery-powered operation.
Can an Addressable Fire Alarm Panel Monitor Smoke Detector Condition? | ANWETECH
2026-07-02 16:47:00
Learn how an analogue addressable fire alarm panel helps engineers check smoke detector condition, device status, curve value, background value and drift value for maintenance and troubleshooting.
LHD Cable vs AT-AS03 Aspirating Smoke Detection for BESS Fire Detection | ANWETECH
2026-06-27 14:43:00
Compare ANWETECH LHD cable and AT-AS03 electrical micro-environment detector for BESS fire detection. Learn when to use fixed-temperature heat detection or active air-sampling multi-parameter early warning.
Linear Heat Detection cable LHD Cable for Battery Energy Storage Cabinet
2026-06-27 14:13:00
Learn how ANWETECH LHD cable provides continuous fixed-temperature heat detection for battery energy storage cabinets, BESS cabinets and critical electrical compartments.
Linear heat detection cable for tank farm  and Rim Seal Fire Detection
2026-06-27 13:16:00
Learn how ANWETECH LHD cable provides continuous heat detection for tank farms, floating roof tank rim seals, cable runs and petrochemical fire risks.
Void Fire Detection Solutions for Ceiling Voids and Raised Floors | ANWETECH
2026-06-27 16:17:00
ANWETECH provides void fire detection solutions for ceiling voids, raised floors, cable spaces and concealed areas using aspirating smoke detection and linear heat detection cable.
4G Auto Dialer for Fire Alarm Remote Notification | AT-GSM01
2026-06-26 18:26:00
Learn how a 4G auto dialer helps fire alarm systems send remote SMS and voice notifications. AT-GSM01 supports N.O., N.C. and voltage trigger inputs.
What Is a 4G Auto Dialer? Alarm System SMS & Voice Notification
2026-06-26 19:05:04
Learn how a 4G auto dialer works in fire alarm and security alarm systems. Discover how AT-GSM01 sends SMS and voice alerts through 4G cellular communication.
Explosion-Proof Audible and Visual Alarm for Oil, Gas and Chemical Plants | ATEX Sounder Beacon
2026-06-25 18:37:00
Learn why oil, gas and chemical plants need ATEX-certified explosion-proof audible and visual alarms. AT-ESS01 provides DC24V fire alarm tone, 90–110dB sound output, 360° LED warning and IP65 protection for hazardous areas.